This generator set belongs to the GSW Series of the PRAMAC brand. This translates into good performance and reliability for professional use such as construction and construction. This is achieved by combining power, reliability and efficiency.
The PRAMAC GSW45Y generator has a brand diesel engine YANMAR 4TNV98T-GPGE 3319 cc and with a maximum power of 36,60 kW. The capacity of its tank is 68 liters of fuel and given its weight of 839 kg makes this generator one of the perfect options to purchase.
Características técnicas:
- Nominal power:
- LTP emergency power: 45,75 kVA / 36,60 kW
- PRP continuous power: 43,43 kVA / 34,74 kW
- Engine:
- Brand: Yanmar
- Model: 4TNV98T-GPGE
- Exhaust emission optimized for 97 / 98 50 Hz (COM): Stage II
- Cooling system: Water
- Number of cylinders and arrangement: 4 in line
- Cilindrada: 3319 cc
- Aspiration: Turbo-charged
- Speed regulator: Mechanical
- PRP Gross Prime Power: 39,7 kW
- Maximum LTP power: 41,8 kW
- Oil capacity: 10,5 liters
- Coolant capacity: 4,2 liters
- Fuel: diesel
- Specific fuel consumption at 75% PRP: 231 g / kWh
- Specific fuel consumption in PRP: 231 g / kWh
- Start System: Electric
- Engine starting capacity: 1,1 kW
- Electric circuit: 12 V
- Alternator:
- Alternator: Mecc Alte
- Model: ECP 32-3S / 4 B
- Voltage: 230V / 400V (Three phase model)
- Frequency: Hz 50
- Power factor: 0.8 cos Ø
- Poles: 4
- Type: Brushless
- AVR standard regulation: DSR
- Voltage tolerance: 1%
- Efficiency at 75% load: 88,7%
- Class: H
- IP Protection: 23
- Size:
- Length: 200 cm
- Width: 92 cm
- Height: 131 cm
- Weight: Kg 839
- Fuel tank capacity: 68 liters
- Fuel tank material: Plastic
- Endurance:
- Fuel consumption at 75% PRP: 8,19 l / h
- Fuel consumption at 100% PRP: 10,92 l / h
- Autonomy at 75% PRP: 8,30 h
- Autonomy at 100% PRP: 6,23 h
- Sound level:
- Guaranteed sound level LWA: 95 dBA
- Noise pressure level at 7mt: 66 dBA
- Installation:
- Total air flow: 79,20 m3 / min
- PRP exhaust gas flow: 8,4 m3 / min
- LTP exhaust gas temperature: 470 ºC
- Current:
- Maximum intensity: 114,85 / 66,04 A (Three phase model)
- Miniature circuit breaker: 125 / 63 A (Three phase model)
- Control panel available:
- Manual control panel MCP:
- Voltmeter (1 phase)
- Ammeter (1 phase)
- Hour counter
- Start / stop switch with key (Includes glow plugs for preheating)
- Emergency stop button
- Protection with alarm:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperatures
- Grounding
- Protection with machine shutdown:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- 3 thermal pole magnet
- Protected panel with lockable door
- Plug Outs (Three phase model only):
- Thermal protections
- 3P + N + T CEE 400V 32A: 1
- 3P + N + T CEE 400V 16A: 1
- 2P + T CEE 230V 16A: 2
- 230V 16A SCHUKO: 1
- Automatic control panel ACP:
- Generator voltage (3 phases).
- Mains voltage
- Generator frequency
- Generator current (3 phases).
- Battery voltage.
- Power (kVA - kW - kVAr).
- Power factor cos φ.
- Account-hours.
- Rpm engine speed
- Fuel level (%).
- Motor temperature (depending on the model)
- Selector for four operation modes: Off - Manual start - Automatic start, -Test automatic.
- Pushbuttons to force grid contactor or generator set contactor.
- Push buttons: start / stop, selection up / down, reset, mode / view selector.
- Remote start available.
- Battery disconnector
- Acoustic alarm
- Automatic battery charging.
- RS232 communications output.
- Password configurable for protection
- Protections with alarm:
- Engine protections: low fuel level, low oil pressure, high engine temperature.
- Group protections: high / low voltage, overload, high / low frequency, start failure, battery voltage out of limits, battery-charge failure.
- Protections with machine shutdown:
- Engine protections: low fuel level, low oil pressure, high engine temperature, low coolant level.
- Group protections: high / low voltage, overload, battery voltage out of limits.
- 3 pole protection switch.
- Grounding
- Emergency stop button
- Protection with door lock with lock.
- Plug Out:
- Terminal block for connection from ACP to the LTS panel. Yes
- 3P + N + T CEE 400V 32A: 1 (Three phase model only)
- Ready for optional RCG remote control (Three phase model only)
- Optional plug kit (Three phase model only)
- Analog manual control MPF (Three phase model only):
- Voltmeter with selector (3 phases)
- Frequency meter
- Ammeter with selector (3 phases)
- Hour counter
- Fuel level indicator
- oil pressure gauge
- Engine temperature indicator
- Start/stop selector switch with key
- Emergency stop button
- Protections with alarm:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- Grounding
- Protections with unemployment:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- Circuit breaker protection: III Poles
- Emergency stop button
- Door protected panel with lock
- Plug Out:
- Individual protection with circuit breaker and ground: Yes
- 3P + N + T 400V 63A IP67: 1
- 3P + N + T CEE 400V 16A IP67: 1
- 230V / 16A 2P + T CEE IP67: 1
- 230V 16A SCHUKO IP68: 1
- Manual control panel MCP:
Optional gadgets:
Accessory | Custom code | Price | ||
STR | Slow trailer GSW 35 / 45Y 30 / 45P | Sy000A000M7 | 566,00 € | Add to cart |
RTR | GSW 35 / 45Y 30 / 45P approved trailer | SY000A000HT | 1841,00 € | Add to cart |
Reviews