This generator set belongs to the GSW Series of the PRAMAC brand. This translates into good performance and reliability for professional use such as construction and construction. This is achieved by combining power, reliability and efficiency.
The PRAMAC GSW165P generator has a brand diesel engine PERKINS 1106A-70TAG2 7000 cc and with a maximum power of 131,20 kW. The capacity of its tank is 350 liters of fuel and its weight is 2038 Kg.
Características técnicas:
- Nominal power:
- LTP emergency power: 164 kVA / 131,20 kW
- PRP continuous power: 152,62 kVA / 122,10 kW
- Engine:
- Brand: Perkins
- Model: 1106A-70TAG2
- Exhaust emission optimized for 97 / 98 50 Hz (COM): Not certified
- Cooling system: Water
- Number of cylinders and arrangement: 6 in line
- Cilindrada: 7000 cc
- Aspiration: Turbo charged
- Speed regulator: Mechanical
- PRP Gross Prime Power: 136 kW
- Maximum LTP power: 149,1 kW
- Oil capacity: 14,9 liters
- PRP lubricant oil consumption: 0,1%
- Coolant capacity: 21 liters
- Fuel: diesel
- Specific fuel consumption at 75% PRP: 199,7 g / kWh
- Specific fuel consumption in PRP: 203,3 g / kWh
- Start System: Electric
- Engine starting capacity: 4,2 kW
- Electric circuit: 12 V
- Alternator:
- Alternator: Mecc Alte
- Model: ECP34-2L
- Voltage: 230V/400V (Three Phase Model)
- Frequency: Hz 50
- Power factor: 0.8 cos Ø
- Poles: 4
- Type: Brushless
- AVR standard regulation: DSR
- Voltage tolerance: 1%
- Efficiency at 75% load: 93,5%
- Class: H
- IP Protection: 23
- Size:
- Length: 340 cm
- Width: 125 cm
- Height: 177 cm
- Weight: Kg 2038
- Fuel tank capacity: 350 liters
- Fuel tank material: Plastic
- Endurance:
- Fuel consumption at 75% PRP: 24,47 l / h
- Fuel consumption at 100% PRP: 32,92 l / h
- Autonomy at 75% PRP: 14,30 h
- Autonomy at 100% PRP: 10,63 h
- Sound level:
- Guaranteed sound level LWA: 97 dBA
- Noise pressure level at 7mt: 68 dBA
- Installation:
- Total air flow: 29,52 m3 / min
- PRP exhaust gas flow: 23,78 m3 / min
- LTP exhaust gas temperature: 484 ºC
- Current:
- Battery capacity: 140 Ah
- Maximum intensity: 411,69 / 236,72 A (Three Phase Model)
- Miniature circuit breaker: 400 / 250 A (Three Phase Model)
- Control panel available:
- Manual control panel MCP:
- Voltmeter (1 phase)
- Ammeter (1 phase)
- Hour counter
- Start / stop switch with key (Includes glow plugs for preheating)
- Emergency stop button
- Protection with alarm:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperatures
- Grounding
- Protection with machine shutdown:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- 3 thermal pole magnet
- Emergency stop button
- Protected panel with lockable door
- Plug Outs (Three Phase Model):
- Optional external power terminal block
- Optional plug kit
- Automatic control panel ACP:
- Generator voltage (3 phases).
- Mains voltage
- Generator frequency
- Generator current (3 phases).
- Battery voltage.
- Power (kVA - kW - kVAr).
- Power factor cos φ.
- Account-hours.
- Rpm engine speed
- Fuel level (%).
- Motor temperature (depending on the model)
- Selector for four operation modes: Off - Manual start - Automatic start, -Test automatic.
- Pushbuttons to force grid contactor or generator set contactor.
- Push buttons: start / stop, selection up / down, reset, mode / view selector.
- Remote start available.
- Battery disconnector
- Acoustic alarm
- Automatic battery charging.
- RS232 communications output.
- Password configurable for protection
- Protections with alarm:
- Engine protections: low fuel level, low oil pressure, high engine temperature.
- Group protections: high / low voltage, overload, high / low frequency, start failure, battery voltage out of limits, battery-charge failure.
- Protections with machine shutdown:
- Engine protections: low fuel level, low oil pressure, high engine temperature, low coolant level.
- Group protections: high / low voltage, overload, battery voltage out of limits.
- 3 pole protection switch.
- Grounding
- Emergency stop button
- Protection with door lock with lock.
- Plug Out:
- Terminal block for connection from ACP to the LTS panel. Yes
- Ready for optional RCG remote control (Three Phase Model)
- Optional external power terminal block (Three Phase Model)
- Optional plug kit (Three Phase Model)
- Analog manual control MPF (Three phase model only):
- Voltmeter with selector (3 phases)
- Frequency meter
- Ammeter with selector (3 phases)
- Hour counter
- Fuel level indicator
- oil pressure gauge
- Engine temperature indicator
- Start/stop selector switch with key
- Emergency stop button
- Protections with alarm:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- Grounding
- Protections with unemployment:
- Low fuel level
- Battery Charger Failure
- Low oil pressure
- High engine temperature
- Circuit breaker protection: III Poles
- Emergency stop button
- Door protected panel with lock
- Plug outlets (Three phase model only):
- Individual protection with circuit breaker and ground: Yes
- 3P + N + T 400V 63A IP67: 1
- 3P + N + T CEE 400V 16A IP67: 1
- 230V / 16A 2P + T CEE IP67: 1
- 230V 16A SCHUKO IP68: 1
- Modular Parallel Frame MPP (Three-phase model only):
- Network: voltage, intensity, frequency.
- KW -kVAr network: Power factor Cos f
- Generator voltage (3 phases).
- Generator frequency
- Generator current (3 phases).
- Generator set power (kVA - kW - kVAr).
- Power factor Cos f.
- kWh kVAh
- Battery voltage.
- Account-hours.
- Rpm engine speed
- Fuel level (%), engine temperature, oil pressure
- 128 × 64 pixel graphic display
- Operating modes: OFF - AMF function-Individual parallel connected to the parallel Individual connected to the network with AMF- Multiple generators interconnected in parallel
- Push button to force network breaker / Contactor or Generator switch / contactor
- Push buttons: start / stop, fault reset, up / down / page / enter multiple parallel selection and power management operation with the use of digital AVR load sharing
- Automatic synchronization and power control (via goveroner speed or ECU)
- Import / export charging base and peak modulation
- PF voltage and control (AVR)
- Digital I / O configuration (12 / 12) and analog inputs (3)
- Integrated PLC programming functions
- Histiral events (up to 500 records)
- Selectable measuring range 120 / 277V and 0-1 / 0-5A
- Remote start and signal lock available
- DC system disconnect switch
- Acoustic alarm
- Automatic battery charger
- 2xRS232 / RS485 / USB communication ports
- PASSWORD configurable for the protection level
- Protection with alarm and machine shutdown:
- Engine protections: low fuel level, low oil pressure, high engine temperature
- Group protections: high / low voltage, overload, high / low frequency, start failure, battery voltage out of limits, battery-charge failure
- Others: overload, short circuit, reverse energy, ground
- Magnetothermal protection: IV motorized poles
- Emergency stop button
- Protected panel with lockable door
- Plug Out:
- Multi-pin connectors (male and female) of the control cable: 2
- Connection cable with 2 multi-pin connectors (10m long): 1
- ETB external power terminal block
- Manual control panel MCP:
Optional gadgets:
Accessory | Custom code | Price | ||
STR | Slow trailer GSW 165 / 200 / 220 Perkins | Sy000A0009I | 1239,00 € | Add to cart |
RTR | GSW 165 / 200 / 220 Perkins approved trailer | SY000A000HX | 4255,00 € | Add to cart |
Reviews
Not yet reviewed